When Windows systems reboot unexpectedly, it can be challenging to determine the root cause. This newsletter provides comprehensive guidance on investigating these mysterious events using event logs, system files, and virtualization-specific tools.
Think of it like a detective story: An unexpected reboot leaves behind clues in the form of event logs, registry entries, and system files. Our job is to piece together these clues to understand what happened in the moments before the system went down.
Key Event IDs to Monitor
The foundation of any reboot investigation starts with understanding the critical event IDs that indicate system behavior:
Event ID | Source | Description | Significance |
6005 | Event Log | Event log service started | System boot initiation |
6006 | Event Log | Event log service stopped | Clean shutdown indicator |
6008 | Event Log | Previous shutdown was unexpected | Dirty shutdown detected |
6009 | Event Log | OS version information | System identification |
41 | Kernel-Power | System rebooted without clean shutdown | Critical reboot indicator |
46 | volmgr | Crash dump initialization failed | Dump creation preparation failure |
161 | volmgr | Dump file creation failed due to error during dump creation | Dump write operation failure |
Important: Event IDs 46 and 161 from volmgr indicate dump file creation failures. These events are crucial for understanding why crash dumps weren't generated during system failures, which can complicate troubleshooting efforts.
Clean vs. Dirty Boot Cycle Analysis
Understanding the difference between clean and dirty boot cycles is crucial for troubleshooting:
Clean Boot Sequence
Event ID 6006 present (clean shutdown)
Event ID 6005 follows normally
No Event ID 6008 or 41
Services shut down properly
Dirty Boot Indicators
Missing Event ID 6006: Event log service was not properly stopped
Event ID 6008: Indicates unexpected shutdown with timestamp discrepancy
Event ID 41: Kernel-Power event showing unclean shutdown
Event IDs 46/161: Dump creation failures during crash
The LastAliveStamp Mechanism
Windows uses a sophisticated mechanism to detect unexpected shutdowns through file and registry tracking:
File Locations by OS Version
OS Version | File Path |
2008R2 - 2016 | C:\Windows\ServiceProfiles\LocalService\AppData\Local\lastalive0.dat |
Windows 10/2019+ | C:\Windows\Servicestate\eventlog\lastalive0.dat |
Registry Location: HKLM\SOFTWARE\Microsoft\Windows\CurrentVersion\Reliability\LastAliveStamp
Event ID 41 Deep Dive
Event ID 41 provides crucial information about the nature of the reboot through its event data parameters:
Parameter | Value = 0 | Value ≠ 0 |
BugcheckCode | Not a bugcheck | System crash/BSOD |
PowerButtonTimestamp | Power button not pressed | Manual power button press |
SleepInProgress | System not sleeping | Sleep operation in progress |
Automatic System Recovery (ASR) Detection
When Event ID 41 shows all parameters as 0, but services were still running, this typically indicates ASR activation:
ASR is like a watchdog: It periodically checks if the OS is responding. If the system becomes unresponsive, ASR forces a hardware reset, similar to how a watchdog timer resets an embedded system.
ASR Symptoms
Event ID 41 with BugcheckCode = 0
PowerButtonTimestamp = 0
Services still running between "last alive" time and actual reboot
Time discrepancy between Event ID 6008 and actual reboot time
Possible Event IDs 46/161 indicating dump creation failures
Physical Hardware Considerations
When investigating unexpected reboots on physical hardware, consider these critical factors:
Hardware Failure Assessment
Vendor Involvement: Consider hardware failure and involve vendor to check the hardware, especially if the unexpected reboot happened multiple times
Power Issues: Consider power issues (spike, loss of power) which might reset the hardware
Thermal Problems: Consider heating issues (Casing, Rack etc) that can cause protective shutdowns
Hardware Diagnostic Steps
Review system logs for hardware errors
Check power supply unit (PSU) specifications and health
Monitor system temperatures and cooling systems
Verify memory modules with memory diagnostic tools
Examine motherboard capacitors and connections
Dump Settings Verification
Proper dump configuration is essential for capturing crash information when unexpected reboots occur:
Critical Dump Settings
Pagefile Size: Ensure that the Pagefile is big enough to hold the dump and, if possible, located on local storage
Storage Space: Ensure that you have enough room on physical devices to store the dump in the location you have defined
Kernel Dump Recommendation: Consider setting the OS to kernel dump as a starting point. Unless you are facing a memory leak, kernel dumps rarely exceed 40 GiB even on systems with 2 TiB or more RAM
Auto Reboot Setting: Consider disabling the auto reboot option so we can see at least if there was a bugcheck even if we cannot create a dump
Dump Configuration Best Practices
Set dump file location to a drive with adequate free space
Configure pagefile to be at least equal to physical RAM + 300MB
Monitor Event IDs 46 and 161 for dump creation failures
Verify dump settings after major system changes
Recommended Pagefile Size = Physical RAM + 300MB (minimum)
VMware-Specific Troubleshooting
Virtual environments require additional investigation techniques, particularly examining VMware logs:
VMware Virtual Watchdog
VMware provides its own ASR mechanism called Virtual Watchdog Timer, which can trigger unexpected reboots when the guest OS becomes unresponsive.
Important: Always check VMware.log files when experiencing unexpected reboots in virtualized environments. These logs often contain crucial information about the reboot cause, even when Windows event logs don't show clear indicators.
VMware Log Analysis
Log Entry | Indication |
VMAutomation_InitiatePowerOff. Tried to soft halt. Success = 1 | clean shutdown Actions -> Guest OS -> Shut Down |
"VMAutomation_InitiatePowerOff. Trying hard poweroff" | Performs a hard power off |
"WinBSOD" with bugcheck parameters | Guest OS crash detected |
VMAutomation_Reset. Trying hard reset | “ Reset ” of the VM from the Vmware console/Interface |
Important: So, even if we don’t have a dump, the VMWare – Logs are a great asset and should be collected..
Hyper-V Clustering Considerations
In clustered Hyper-V environments, monitor for Event ID 1069 which indicates cluster resource heartbeat failures:
This event can trigger unexpected VM shutdowns when the cluster detects unresponsive resources, similar to ASR behavior on physical hardware.
Enhanced Troubleshooting Workflow
Check Event Log Sequence: Look for clean vs. dirty boot patterns
Analyze Event ID 41: Examine BugcheckCode and PowerButtonTimestamp
Review Dump Creation Events: Check for Event IDs 46 and 161 from volmgr source
Review Time Discrepancies: Compare Event ID 6008 time with actual reboot time
Check Service Activity: Look for services running between "last alive" and reboot
Hardware Assessment: Consider ASR, power issues, or thermal problems
Virtual Environment: Request VMware.log or check Hyper-V cluster events
Memory Dump Configuration: Verify and test dump settings for future analysis
Hardware Diagnostics: Involve vendor support for recurring issues
Proactive Monitoring Recommendations
Implement performance monitoring to capture system behavior before unexpected reboots:
Key Performance Counters
Memory utilization and paging file usage
Processor and disk performance
Network interface statistics
Hyper-V specific counters (if applicable)
Performance monitoring is like having a black box recorder: It captures system behavior leading up to the "crash," providing valuable insights into what conditions existed before the unexpected reboot occurred.
Advanced Memory Snapshot Techniques
For persistent issues, consider memory snapshot collection:
VMware: Use VMSS2CORE tool to convert memory snapshots to dump files
Hyper-V: Leverage WinDBGx for direct snapshot analysis
Physical Systems: Configure kernel dump settings with adequate storage